EPSON

Replacing the Roller Assembly Kit

You need to replace the parts on the Roller Assembly Kit after scanning every 100,000 times.
Removal part
Part number
Number of scanning
Roller Assembly Kit
B12B813501
100,000
To replace the Roller Assembly Kit, follow the steps below.
Turn off the scanner.
Remove all paper from the input tray.
Unplug the power cord from the product.
Open the Automatic Document Feeder (ADF) cover.
Press the hook on both sides of the pickup roller cover, then open the cover.
Slide and remove the installed pickup roller.
Attach the new pickup roller to the correct position.
Important:
Do not touch the surface of the roller.
Close the pickup roller cover.
Press in the hooks on both sides of the retard roller cover, and then open the cover.
Grip the shaft of the retard roller, lift it up, and then remove the retard roller.
Attach the new retard roller to the correct position.
Press the shaft of the retard roller down until you hear it click into place.
Close the retard roller cover.
Close the ADF cover.
Plug the power cord, and then turn on the scanner.
Start Epson Scan Settings.
Windows:
Start > All Programs or Programs > EPSON > EPSON Scan > Epson Scan Settings
Mac OS X:
Select Applications > EPSON Software > EPSON Scan Settings.
Click Maintenance.
Click Reset, and then click OK.
Important:
Make sure you reset the counter after replacing the Roller Assembly Kit.